ID |
CVE-2024-2856
|
Sažetak |
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
Reference |
|
CVSS |
Base: | 9.0 |
Impact: | 10.0 |
Exploitability: | 8.0 |
|
Pristup |
Vektor | Složenost | Autentikacija |
NETWORK |
LOW |
SINGLE |
|
Impact |
Povjerljivost | Cjelovitost | Dostupnost |
COMPLETE |
COMPLETE |
COMPLETE |
|
CVSS vektor |
AV:N/AC:L/Au:S/C:C/I:C/A:C |
Zadnje važnije ažuriranje |
26-03-2024 - 03:16 |
Objavljeno |
24-03-2024 - 07:15 |